    External Device Pc Connection Serial Interface Subd9, supplied by Eppendorf AG, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/external+device+pc+connection+serial+interface+subd9/Equipment+Connection+Module/fda_document____cdrh_docs_slash_pdf14_slash_k142207-48-209-238
    Average 93 stars, based on 1 article reviews
    external device pc connection serial interface subd9 - by Bioz Stars, 2026-09
    93/100 stars

    Images

    Related Articles

    Microscopy:

    Article Title:
    Article Snippet: .. 1.4 mm/s M ot or M od ul e Step Motors X-,Y-,Z- Module X-,Y-,Z- Module Step Size < 20 nm (calculated resolution) Not known Mechanical Adjustability >80 mm Dimensions Module (X,Y,Z): 129 mm x 51 mm x 36 mm (W x D x H) Drive Unit: 57 mm x 138 mm x 94 mm (W x D x H) Weight Motor module (complete): 2.15 kg Module (X,Y,Z): 570g Not known Maximum Traveling Distance 20 mm Coarse: 22mm Fine: 10mm Swivel Joint Direction of Rotation -45° – +90° Not known Feature TransferMan® 4m Micromanipulator Eppendorf AG (Proposed) NAI-5 Micromanipulator Set Narishige Col. Ltd System (K120877) Capillary Exchange Direction of rotation: forward (swivel out) Sample Replacement Direction of rotation: backward (swivel in) Operating Angle of Angle Head 0° – 90° Microscope Compatibility All major microscope brands: Leica, Nikon, Olympus, and Zeiss All major microscope brands: Leica, Nikon, Olympus, and Zeiss C on tr ol U ni t Dimensions 205 mm x 288 mm x 152 mm (W x D x H) 70 mm x 100 mm x 120 mm (W x D x H) Weight Control board: 1.8 kg (includes mains/power supply device) Not known Control Mechanism Dual Speed joystick Joystick Working range Coarse, fine, x-fine Coarse, fine Programmable Yes No External device/PC Connection Serial interface SubD9, male Not known Speed Control Proportional and dynamic kinetics Side-by-Side Comparison of the CellTram® Microinjectors with the IM-11 Pneumatic Microinjector Feature CellTram® Microinjectors Eppendorf AG (Proposed) IM-11 Pneumatic Microinjector Narishige Co., Ltd. (K113712) G en er al Intended Use Intended for use in Intra-Cytoplasmic Spermatozoa Injection (ICSI) procedures to aspirate and inject sperm into oocytes. .. Intended for use for IntraCytoplasmic Sperm Injection (ICSI) procedures to aspirate and inject sperm into oocytes, and to hold oocytes during the ICSI procedure Microinjector Type CellTram® Air (air transfer medium) CellTram® Oil (oil transfer medium) CellTram® vario (oil transfer medium, coarse/fine adjustment) Air transfer medium Operation Manual microinjection Manual microinjection Minimum Adjustment Volume <0.2 μL Not known Adjustment total volume 2,640 μL A ir Applications Gentle holding of larger cells, e.g. oocytes Manual microinjection, aspiration and dispensing of cells (e.g. sperms) Holding oocytes Manual aspiration of sperm into injection pipette Microinjection of sperm into oocytes Type Manual pressure Manual pressure Pressure Generation Piston/cylinder system, filled with air, maintenance-free Pneumatic Max Pressure 2,900 hPa Not known Minimum Setting Volume <200 nL Not known Feature CellTram® Microinjectors Eppendorf AG (Proposed) IM-11 Pneumatic Microinjector Narishige Co., Ltd. (K113712) Total Setting Volume 2,640 μL Not known Change in Volume (per dial revolution) 88 μL coarse: 1.0 mL fine: 250 μL Max Range 15 mm (air) 40 mm (coarse and fine combined) 30 mm coarse 17 mm fine O il Applications Gentle holding of larger cells, e.g. oocytes Manual microinjection, aspiration and dispensing of cells (e.g. sperms) Not Applicable Type Manual hydraulic Pressure Generation Piston/cylinder system, filled with oil Max Pressure 20,000 hPa Minimum Setting Volume <20 nL Total Setting Volume 960 μL Change in Volume (per dial revolution) 9.6 μL Max Range 50 mm va ri o Applications Gentle holding of larger cells, e.g. oocytes Manual microinjection, aspiration and dispensing of cells (e.g. sperms) Manual aspiration, dispensing, and removal of cells and organelles (e.g. polar bodies).



    Similar Products

    93
    Eppendorf AG external device pc connection serial interface subd9
    External Device Pc Connection Serial Interface Subd9, supplied by Eppendorf AG, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/external+device+pc+connection+serial+interface+subd9/Equipment+Connection+Module/fda_document____cdrh_docs_slash_pdf14_slash_k142207-48-209-238
    Average 93 stars, based on 1 article reviews
    external device pc connection serial interface subd9 - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    Image Search Results